Hi TheDarkSide,

Is the issue with the NULL transport key command the change [4043] shows in README CC2530.txt of ZStack 2.5.1a?

 - [4043] Corrected an issue with saving/restoring Address Manager NV items
   that was causing unnecessary transport key commands to be sent to already
   commissioned devices when a new device joined the Coordinator/TrustCenter.

I have some ED with NV_INIT and NV_RESTORE, and had joined a ZB network. After I turn off and on the coordinator several time, the EDs won't join back the network any more. The ED just keep sending beacons but I don't see ZC responds to the beacons. The only way to make ED joins back to ZC is to reset the power of ED. Do you think this is the same problem?