Browse latest Browse all 116964

Forum Post: RE: TimeApp BTool

$
0
0

Hello,

 Note: I use BTool Application v1.30d

I fall back to TI demo SWRU301A page 18. After scanning and establishing I can read using characteristic UUID  “F1:FF” and get handle (0x0022) and value (01). Everything for reading is fine.

As described for writting, with handle 0x0022 and value 7 the display shows “Char 1: 7”, but I get at the end always an error? (see below)

    

29] : <Tx> - 10:53:47.765

-Type                      : 0x01 (Command)

-Opcode                  : 0xFD92 (GATT_WriteCharValue)

-Data Length           : 0x05 (5) byte(s)

 ConnHandle           : 0x0000 (0)

 Handle                   : 0x0022 (34)

 Value                     : 07

Dump(Tx):

01 92 FD 05 00 00 22 00 07

 

------------------------------------------------------------------------------------------------------------------------

[30] : <Rx> - 10:53:47.781

-Type                      : 0x04 (Event)

-EventCode             : 0xFF (HCI_LE_ExtEvent)

-Data Length           : 0x06 (6) bytes(s)

 Event                     : 0x067F (GAP_HCI_ExtentionCommandStatus)

 Status                    : 0x00 (Success)

 OpCode                 : 0xFD92 (GATT_WriteCharValue)

 DataLength            : 0x00 (0)

Dump(Rx):

04 FF 06 7F 06 00 92 FD 00

 

------------------------------------------------------------------------------------------------------------------------

[31] : <Rx> - 10:53:47.921

-Type                      : 0x04 (Event)

-EventCode             : 0xFF (HCI_LE_ExtEvent)

-Data Length           : 0x06 (6) bytes(s)

 Event                     : 0x0513 (ATT_WriteRsp)

 Status                    : 0x00 (Success)

 ConnHandle           : 0x0000 (0)

 PduLen                  : 0x00 (0)

Dump(Rx):

04 FF 06 13 05 00 00 00 00

 

------------------------------------------------------------------------------------------------------------------------

[32] : <Error> - 10:54:27.782

Message Response Timeout

Name = GATT_WriteCharValue

Opcode = 0xFD92