Forum Post: RE: SensorTag CC2541 - reporting rate

$
0
0

Hi again

Thanks for keeping me on the track!

well i managed to increase the reporting rate

which I could monitor in the BLE

23:01:17.051 > ATT_HandleValueNotification - status=0 h=75 n=4 0F FF 3D 8B

23:01:17.081 > ATT_HandleValueNotification - status=0 h=75 n=4 0F FF 3E 8B

23:01:17.146 > ATT_HandleValueNotification - status=0 h=75 n=4 08 FF 3E 8B

23:01:17.206 > ATT_HandleValueNotification - status=0 h=75 n=4 08 FF 3E 8B

23:01:17.241 > ATT_HandleValueNotification - status=0 h=75 n=4 06 FF 3E 8B

23:01:17.302 > ATT_HandleValueNotification - status=0 h=75 n=4 06 FF 41 8B

23:01:17.333 > ATT_HandleValueNotification - status=0 h=75 n=4 04 FF 41 8B

23:01:17.393 > ATT_HandleValueNotification - status=0 h=75 n=4 04 FF 3E 8B

23:01:17.458 > ATT_HandleValueNotification - status=0 h=75 n=4 00 FF 3E 8B

23:01:17.489 > ATT_HandleValueNotification - status=0 h=75 n=4 00 FF 3E 8B

23:01:17.549 > ATT_HandleValueNotification - status=0 h=75 n=4 0B FF 3E 8B

23:01:17.584 > ATT_HandleValueNotification - status=0 h=75 n=4 0B FF 3B 8B

23:01:17.645 > ATT_HandleValueNotification - status=0 h=75 n=4 01 FF 3B 8B

23:01:17.706 > ATT_HandleValueNotification - status=0 h=75 n=4 01 FF 3C 8B

23:01:17.741 > ATT_HandleValueNotification - status=0 h=75 n=4 01 FF 3C 8B

23:01:17.801 > ATT_HandleValueNotification - status=0 h=75 n=4 01 FF 3C 8B

23:01:17.831 > ATT_HandleValueNotification - status=0 h=75 n=4 01 FF 3C 8B

23:01:17.896 > ATT_HandleValueNotification - status=0 h=75 n=4 01 FF 3E 8B

23:01:17.956 > ATT_HandleValueNotification - status=0 h=75 n=4 05 FF 3E 8B

23:01:17.991 > ATT_HandleValueNotification - status=0 h=75 n=4 05 FF 41 8B

23:01:18.051 > ATT_HandleValueNotification - status=0 h=75 n=4 07 FF 41 8B

23:01:18.082 > ATT_HandleValueNotification - status=0 h=75 n=4 07 FF 3E 8B

 

 

 

 * CONSTANTS  */

// How often to perform sensor reads (milliseconds)

#define TEMP_DEFAULT_PERIOD                   1000

 #define HUM_DEFAULT_PERIOD                    1000

#define BAR_DEFAULT_PERIOD                    10

what I would like to understand is how I can control which precision the pressure sensor from Epcos is set to. According to the product sheet: page 5 top section

http://www.epcos.com/web/generator/Web/Sections/ProductCatalog/Sensors/PressureSensors/T5400-ApplicationNote,property=Data__en.pdf;/T5400_ApplicationNote.pdf

There are 4 different levels of precision:where do I set this in the sample project?