Forum Post: RE: How to change to 200kbps BW configuration of CC1120 from your sample settings?

The noise floor becomes higher about 50dB not just 10dB. The reproduction ratio with CC1120EM is not so high. However, it's easy to reproduce the problem with CC1120+CC1190EM.
Could you please try the following procedure to reproduce with using CC1120+CC1190EM?
1. Select Range Expander to 1190 with HGM
2. Select 869MHz, 1.2kbps, 2-FSK, 25kHz in continuous RX tab
3. Change carrier frequency 915MHz and BW is 200kHz

I think that you can see the error like the attached image below.

I would like to know the route cause of this problem.

Best regards,
Masa