Forum Post: RE: Sensitivity different od receiving packet via RFStdio from Receiving after configure the CC1125 from CCS

$
0
0

If you use Sniff mode make sure the preamble length matches the wake up interval. Also, make sure the TX interval is long enough if you send more than one packet (receiver needs time to receive current packet and then re-start RX loking for the new packet).